E44-127 · Hydraulic System Contamination and Stick-Slip · Electro-Hydraulic Servo Valve · ★★★
Oil at NAS level 11 (exceeded), spool sticking, actuator dead, positioning out of tolerance
[Sticking] Particles jam the spool.
[Calculation] Particles >5 μm jam the clearance, causing valve failure.
[Design Omission] Oil cleanliness was not brought to NAS level 7, causing sticking.
1) Control oil cleanliness to within NAS level 7; because particles >5 μm jam the clearance, this prevents sticking;
2) Add a closed-loop return-line fine filter (≤5 μm); because continuous filtration keeps the oil clean, this preserves cleanliness;
3) Add online particle-count monitoring with warning; because exceeding the limit triggers an alarm, this enables early filter change;
4) Add a guard filter upstream of the servo valve; as a double safety, this stabilizes operation;
5) Change the oil and filter elements on schedule; because aging generates particles, this keeps the oil clean;
6) Assemble the system in a clean room; because this reduces particle ingress, contamination is controlled at the source;
7) Measure valve response on the test run to confirm no sticking; because design requirements must be verified by test, this confirms acceptance;
8) Write cleanliness control into the hydraulic specification; because contamination is the root cause, the specification enforces prevention of recurrence.
GB/T 3766-2015 Hydraulic fluid power - General technical conditions