E44-179 · Hydraulic System Contamination and Stick-Slip · Bladder Accumulator · ★★
Nitrogen leakage dropped the precharge pressure from 6 MPa to 3 MPa, and system pressure fluctuated by ±1.5 MPa
[Nitrogen Leak] Leaks at the bladder or gas valve lower the precharge.
[Instability] When precharge is lost, pulsation absorption capacity drops and pressure fluctuates.
[Design Omission] No periodic leak check and no recharging were provided, causing instability.
1) Check accumulator nitrogen leakage and recharge on schedule; because nitrogen leakage dropped precharge from 6 to 3 MPa and caused ±1.5 MPa fluctuation, leak checking preserves precharge;
2) Fit the gas valve with leak-tight seals; because valve leakage was the path, sealing prevents leakage;
3) Set the precharge pressure to the duty cycle; because lost pressure reduces pulsation absorption, pressure setting restores it;
4) Choose a fatigue-resistant bladder; because fatigue causes leakage, selecting fatigue-resistant material prevents it;
5) Monitor pressure fluctuation with alarm; because it forewarns of abnormal operation, monitoring gives early notice;
6) Provide a standby accumulator; because a single unit losing charge causes failure, a backup maintains operation;
7) Verify on the test run that pressure fluctuation stays within the limit; because design requirements must be verified by test, this confirms acceptance;
8) Write leak checking into maintenance; because the original lack of inspection is the root cause of pressure loss, maintenance must include it.
GB/T 3766-2015 Hydraulic fluid power - General technical conditions