E44-485 · Filter Clogging and Contamination · Resin Trap Filter 0.1mm · ★★
Broken resin beads plug the screen, differential pressure rises, outlet turbidity reaches 2NTU>0.5, and ion-exchange performance drops
[Mechanism] Crushed resin particles jam the screen.
[Calculation] Broken beads d=0.1mm occupy the screen openings, 30% jam, v rises, Δp exceeds the limit, and turbidity reaches 2.
[Design Omission] Broken beads were not screened out and backwashing was too strong, so the screen plugged.
1) Screen the resin regularly to remove broken beads; since 30% of openings jammed and turbidity reached 2, screening keeps water flowing;
2) Control backwash intensity to prevent resin breakage; since strong backwashing crushes beads, intensity control protects them;
3) Make the screen slightly more tolerant of fine beads; since narrow openings jam, a slightly wider opening avoids it;
4) Monitor outlet turbidity; since exceeding the limit signals degraded performance, monitoring catches it;
5) Control resin age during make-up to prevent aged breakage; since old resin crushes, age control prevents it;
6) Add a pre-filter upstream to remove fines; since broken beads were abundant, pre-filtration removes them;
7) Flush on schedule to prevent buildup; since deposits cause plugging, scheduled flushing removes them;
8) Write resin screening into the ion-exchange procedure; since beads were never screened, the root cause of breakage, the ion-exchange procedure provides the check.
GB/T 26114-2010 Filters for liquid filtration