E44-332 · Excessive Piping Resistance and Pressure Drop · Rubber hose bent at R=2D · ★★
A 2D bend radius flattens the section, raises local loss coefficient ζ=3, gives Δp=0.08MPa, and cuts flow by 20%
[Mechanism] Too small an R collapses the hose section and shrinks the flow passage.
[Calculation] ζ=3 gives Δp=0.08MPa and cuts flow by 20%.
[Design Omission] No minimum bend radius ≥5D controlled and no securing - the hose collapsed.
1) Hold the hose bend radius ≥5D and fit retaining clips, since R=2D caused collapse, ζ=3, Δp=0.08 and 20% flow loss, keeping it round and lowering resistance;
2) Switch to a larger-bore hose to cut collapse, since small hoses collapse easily, upsizing the bore;
3) Add a helix support to prevent collapse, since vacuum suction flattens it, providing support;
4) Check the local loss at the bend, since collapse causes loss, accounting for the loss;
5) Avoid sharp bends in favor of gentle arcs, since sharp bends collapse badly, using smooth arcs;
6) Periodically inspect for flattening and replace hoses, since aged hoses collapse easily, inspecting hoses;
7) Leave slack in the layout, since pulling flattens the hose, leaving slack;
8) Write the bend radius into the installation, since the missing radius control was the root cause, closing the loop at installation.
GB/T 20801.3-2020 Design code for industrial metallic piping