E44-449 · Two-Phase Flow and Gas Binding · Gas in Mechanical Seal · ★★★
Gas made the seal-chamber pressure pulsate, the seal faces ran dry, leakage increased, and the mechanical-seal life dropped to one month.
[Pulsating Wear] Gas made the chamber pressure pulsate and the faces run dry.
[Leakage] The wear increased leakage and cut seal life to one month.
[Design Omission] No venting and pressure stabilization of the chamber, and no dry-wear-resistant seal selected; gas caused seal failure.
1) Provide venting and pressure stabilization in the seal chamber to prevent dry running; gas caused pulsation, dry wear, increased leakage, and one-month life, so venting and stabilized pressure keep the faces lubricated;
2) Select a dry-running-resistant mechanical seal (e.g., flushed double seal); dry running caused wear, so choose a wear-resistant type;
3) Use an external flush of seal liquid to keep the faces lubricated; gas-prone service dries the faces, so flush externally;
4) Control the gas fraction ≤3%; more gas means more dry running, so control gas;
5) Monitor chamber pressure to detect pulsation early; pulsation develops gradually, so monitor pressure;
6) Periodically inspect leakage; wear causes leakage, so check for it;
7) Prevent gas entry at the pump inlet; gas causes chamber pulsation, so keep gas out;
8) Write chamber venting and stabilization into the design; gas entrainment was the root cause of seal failure, so the design gates it.
GB/T 5657-2013 Technical specifications for centrifugal pumps