E44-202 · Other · Pulsating-Line Pressure Gauge · ★★
The dampening fluid had dried out; pulsation made the pointer flutter and the reading was hard to take.
[Fluid Dry] Lost dampening fluid leaves no damping.
[Flutter] Pulsation makes the pointer flutter.
[Design Omission] No fluid refill and no vibration-resistant gauge; flutter resulted.
1) Refill pressure-gauge dampening fluid periodically; dry fluid lets pulsation flutter the pointer and harden reading, so refill to keep damping;
2) Choose a liquid-filled vibration-resistant gauge; the duty vibrates, so choose vibration-resistant;
3) Fit a pulsation damper before the gauge; pulsation is high, so add damping;
4) Install away from direct vibration sources; vibration transmits flutter, so isolate the mount;
5) Periodically check fluid level and reading; it dries gradually, so inspect periodically;
6) Choose a suitable range to prevent flutter overshoot; a wrong range flutters, so fit the range;
7) Verify a steady pointer and accurate reading on commissioning; design requirements need measured confirmation, so confirm at delivery;
8) Bring dampening maintenance into instrument management; the original lack of refill was the root cause of flutter, so management must include it.
GB/T 1226-2010 General pressure gauges