E44-286 · Valve Selection and Internal Leakage · Direct-acting pressure reducing valve DN40 · ★★
As flow increased, outlet pressure rose by 0.15MPa (it should have dropped), the downstream overpressure protection tripped, and control became abnormal.
[Reverse Action] A mismatch between the diaphragm effective area and the spring made the opening rise as flow increased.
[Mismatch] The trim force balance was designed backwards, so pressure rose with flow.
[Design Omission] The valve was not selected by characteristic and no flow-pressure test was run — the reducing valve acted in reverse.
1) Select a direct-acting valve from the flow-pressure characteristic; the mismatch made pressure rise 0.15MPa with flow, so make it act correctly;
2) Run a full-range flow-pressure test to check the characteristic; a reversed characteristic is hard to notice, so verify it;
3) Add a back-pressure tank downstream to smooth fluctuations; reverse action causes overpressure, so stabilize;
4) Fit a downstream safety valve as backup; overpressure had already tripped it, so protect;
5) Switch to a pilot-operated reducing valve; the direct-acting type is prone to reverse action, so change type;
6) Periodically calibrate outlet pressure against flow; drift is gradual, so monitor;
7) Limit maximum flow to the design range; outside it reverse action is likely, so limit flow;
8) Write the characteristic selection into the design; the mismatch was the cause of reverse action, so gate it at design.
GB/T 12244-2006 Pressure reducing valves - General requirements