E44-346 · Excessive Piping Resistance and Pressure Drop · 3mm flange mismatch · ★★
A 3mm flange mismatch creates an internal step, local ζ=0.8, Δp=0.03MPa, and brings erosion
[Mechanism] The mismatched joint creates an internal step and an abrupt passage, raising ζ.
[Calculation] ζ=0.8 gives Δp=0.03MPa and brings erosion.
[Design Omission] No centering and no mismatch control ≤1mm - the mismatch kept resistance high.
1) Center the flange joints to hold mismatch ≤1mm, since 3mm caused a step, ζ=0.8, Δp=0.03 and erosion, centering to cut resistance;
2) Use concentric reducers to transition the mismatch, since abrupt changes lose energy, transitioning smoothly;
3) Check the local loss at the mismatch, since the step causes loss, accounting for it;
4) Inspect alignment by bore camera after welding, since blind welds misalign easily, checking alignment;
5) Add supports and hangers to prevent settlement-induced mismatch, since settlement misaligns, supporting the pipe;
6) Periodically inspect joints for steps, since displacement misaligns them, inspecting joints;
7) Boost pump head to cover the local loss, since the end needs pressure, adding head;
8) Write mismatch control into assembly, since the missing control was the root cause, closing the loop at assembly.
GB/T 20801.3-2020 Design code for industrial metallic piping