Knowledge Base › Fluid Systems Error Case › Valve Flashing and Cavitation Noise

Valve Flashing and Cavitation Noise

E44-844 · Throttling Noise and Vibration · Control valve · ★★★

Problem Description

A DN100 control valve with 150℃ saturated water at 0.6MPa inlet and 0.15MPa outlet, below the saturation pressure, flashed with 88dB(A) noise

Root Cause

[Mechanism] The downstream pressure drops below the medium's saturation vapor pressure, and the liquid flashes directly into vapor; the two-phase flow scours the trim and emits cavitation noise.
[Calculation] Outlet p2=0.15MPa<saturation pressure pv(150℃)=0.476MPa, so flashing occurs; the two-phase velocity rises from 2m/s to 18m/s.
[Design Omission] No flashing avoidance, no outlet-pressure verification, no cavitation-resistant trim.

Corrective Solution

1) Avoid flashing (raise the outlet pressure above >0.48MPa, or move the valve to a subcooled section), since the original p2=0.15<0.476MPa flashed, thus avoiding flashing prevents cavitation;
2) Verify the outlet pressure (p2≥pv+0.05MPa), since low pressure flashes and verification avoids it, thus verifying pressure;
3) Replace with cavitation-resistant trim (a tungsten carbide seat), since the two-phase flow erodes the original trim and the replacement resists it, thus replacing the trim;
4) Use multi-stage pressure reduction (3 stages each dropping 0.15MPa), since concentration flashes and splitting eases it, thus staging;
5) Monitor the cavitation (listening + temperature measurement, alarm on noise >85dB(A)), since gradual flashing approaches erosion and early detection catches it, thus monitoring cavitation;
6) Run a flashing test (adjust p2 and record the phase-change point), since the lack of testing left the flashing undetected and the test reveals the threshold, thus testing cavitation;
7) Control the temperature to prevent flashing (lower the inlet temperature to 10℃ subcooling), since heat flashes and control cools, thus controlling temperature;
8) Write the flashing avoidance and pressure verification into the calculation sheet, since the original lack of avoidance is the root cause of flashing and locking it in closes the loop, thus controlling it in the calculation.

Checklist

Reference

GB/T 17213.1-2015 Industrial-process control valves