Biased Flow from Aged Valve Characteristics

E44-780 · Uneven Flow Distribution · Valve Aging · ★★

Problem Description

The valve characteristics aged, the flow characteristic deviated >10%, and the control was biased

Root Cause

[Mechanism] Wear or corrosion of the valve trim drifts the flow characteristic.
[Calculation] Aging drifts the equal-percentage characteristic toward quick-opening, biasing the flow >10%.
[Design Omission] The valve was not replaced and the characteristic was not calibrated, so it had to be replaced.

Corrective Solution

1) Replace the aged valve (replace once trim wear exceeds 0.5mm), because the aging drifted the equal-percentage characteristic to quick-opening and biased the flow >10%, throwing the control off, thereby restoring the characteristic by replacing the valve;
2) Verify the flow characteristic (measure the inherent characteristic curve with actual flow and compare), because off-design conditions bias the flow and verification reveals it, thereby restoring accuracy by calibration;
3) Run a characteristic test (measure the flow-versus-opening curve over the full stroke), because the omitted test let the change go unnoticed, thereby revealing the true characteristic;
4) Check for aging (measure internal leakage/stroke periodically, alarm above 8% drift), because gradual aging widens the bias and early detection helps, thereby checking for aging;
5) Control media corrosion (choose corrosion-resistant trim or lining), because corrosion ages the valve and resistance extends its life, thereby controlling corrosion and extending life;
6) Check the characteristic at intervals (measure the characteristic curve every quarter), because gradual bias is invisible and periodic checks prevent it, thereby checking the characteristic against bias;
7) Choose aging-resistant valves (metal hard seal or erosion-resistant), because aging biases the flow and aging resistance keeps it steady, thereby reducing the bias;
8) Write the valve replacement and characteristic calibration into the maintenance card, because the omitted replacement was the root cause of the aging and the maintenance card enforces it, keeping the valve as new.

Checklist

Reference

GB/T 12224-2015 Steel valves