E44-1049 · Two-Phase Flow and Gas Binding · Separator · ★★
Poor separation, liquid carryover, fouling
[Mechanism] The separator was undersized and the velocity too high; gas and liquid were not fully separated, and the gas carried liquid over.
[Calculation] DN400 separator; throughput exceeded design by 30%; shell v=0.8m/s (should be ≤0.3); separation efficiency 82% (should be ≥98%); liquid carryover 5%.
[Design Omission] No proper vessel volume selected, no velocity check, and no mist eliminator.
1) Replace with a larger-volume separator (8m³ instead of 5); a small vessel causes carryover, and a larger one separates properly, raising efficiency;
2) Check the shell velocity ≤0.3m/s (was 0.8); high velocity causes carryover, and limiting it separates the phases, suppressing carryover;
3) Add a mist-elimination pad (150mm wire mesh); carryover caused fouling, and the pad removes the liquid, cleaning the gas;
4) Reduce the inlet velocity (enlarge diameter to stabilize flow); high velocity causes carryover, and lowering it separates the phases, suppressing carryover;
5) Run a separation-efficiency test (≥98% passes); carryover was never checked, so measured data confirms efficiency, sizing the separation by data;
6) Install outlet liquid monitoring (carryover ≤1%); carryover first shows up as liquid, so early warning gives separation monitoring;
7) In operation, keep throughput ≤design (divert flow when exceeded); overloading causes carryover, and controlling the rate separates the phases, preventing carryover in service;
8) Write separator selection and velocity check into the specification; the root cause of poor separation is undersizing and high velocity, so the specification gates it.
GB/T 150.1-2011 Pressure vessels