E44-382 · Water Hammer and Pressure Surge · Pressure gauge, no buffering · ★★
The water-hammer wave drove the pointer past full scale, the Bourdon tube permanently deformed, and the gauge failed and had to be replaced.
[Mechanism] The wave pressure transiently exceeds the gauge range and slams the pointer to full scale.
[Calculation] The overrange deformed the Bourdon tube and ruined it.
[Design Omission] No siphon/damper was fitted and no impact-resistant gauge was selected, so the hammer ruined the gauge.
1) Fit a siphon loop or damper before the pressure gauge, because the wave slammed the pointer, deformed the tube and ruined it; hence buffering limits the impulse;
2) Select an impact-resistant (liquid-filled) pressure gauge, because ordinary gauges ruin easily; hence impact-resistant;
3) Select the gauge range ≥1.5 times the hammer peak, because the peak exceeds the range; hence larger range;
4) Use a remote pressure transmitter instead of a local gauge, because local gauges get smashed; hence remote transmission;
5) Determine the gauge range from the hammer peak, because estimates fall short; hence peak-based setting;
6) Periodically calibrate the gauge to prevent deformation, because deformation is gradual; hence calibration;
7) Cut the peak in the piping to reduce transmission, because the source wave is large; hence cut the source;
8) Write gauge protection into the design, because the lack of buffering was the root cause of damage; hence design control.
GB/T 32284-2015 Code for design of pump stations - Water hammer protection