E44-383 · Water Hammer and Pressure Surge · Air vent sudden closure · ★★
Sudden closure of a high-point air vent trapped an air pocket; the downstream water column collided to generate Δp=1.1MPa beyond the allowable limit, and the valve well geysered.
[Mechanism] The valve closure traps the air and the downstream column collides.
[Calculation] Δp=1.1 exceeded the allowable limit and geysered.
[Design Omission] The air vent was not slow-closing and air trapping was not prevented, so sudden closure caused hammer.
1) Change the air vent to slow-closing or limit its closure speed, because sudden closure trapped the air, Δp=1.1 exceeded the limit and geysered; hence slow closure prevents trapping;
2) Provide a double-acting speed-controlled air valve, because ordinary valves close suddenly; hence controlled;
3) Check the air-trap collision Δp and up-rate the pipe, because the exceeded limit geysered; hence higher rating;
4) Provide drainage in the valve well to prevent flooding, because geysering floods it; hence drainage;
5) Cut the peak in the piping to reduce transmission, because the source wave is large; hence cut the source;
6) Periodically adjust the valve speed, because drift makes it sudden; hence speed adjustment;
7) Recheck by water-hammer simulation, because estimates fall short; hence simulation;
8) Write air-vent protection into the design, because the original sudden closure was the root cause of the hammer; hence design control.
GB/T 32284-2015 Code for design of pump stations - Water hammer protection