E44-232 · Pump Selection & Cavitation · Hot Medium Pump IH80-65-160 · ★★
The suction pipe was not insulated, so in summer the medium rose from 80 to 88 degrees Celsius, Pv rose and NPSHa fell from 3.0 to 2.2m against NPSHr of 2.6m
[Cavitation] Without insulation the medium warms inside the pipe, Pv rises and NPSHa falls, causing cavitation.
[Calculation] An 8 degree Celsius temperature rise increases Pv by about 0.02MPa and the Pv/rho*g term in NPSHa by about 2m, so NPSHa falls from 3.0 to 2.2m.
[Design Omission] The suction pipe insulation was missing and the medium temperature entering the pump was not controlled, so the warming caused cavitation.
1) Complete the suction pipe insulation to stop the medium warming: the insulation reduces the heat gain, so the temperature is controlled and Pv stays stable;
2) Check the medium temperature entering the pump against the highest ambient temperature: summer is the most severe condition, so the worst case is covered;
3) Route the suction pipe to avoid sections in direct sunlight: radiant heating raises the temperature, so the pipe is kept cooler;
4) Shorten the suction pipe to reduce the residence time and the warming: a long residence allows the medium to warm, so the warming is reduced;
5) Recalculate NPSHa using the Pv at the warmed temperature: Pv follows the temperature, so the design value becomes realistic;
6) Where necessary apply cooling to the suction pipe: active cooling lowers Pv, so this helps;
7) Commission the pump under the hot condition and measure the inlet pressure, confirming no cavitation: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the suction pipe insulation in the design: the original absence of insulation was the root cause, so the design must always include it.
GB/T 13006-2013 Centrifugal Pumps - NPSH