Suction valve partly closed throttles the inlet and causes cavitation

E44-233 · Pump Selection & Cavitation · Process Pump IS80-50-200 · ★★

Problem Symptom

The valve on the suction side was half open and throttling, the differential head was 1.0m, NPSHa fell from 3.2 to 2.2m against NPSHr of 2.7m, and throttling cavitation occurred

Root Cause

[Cavitation] Throttling at a suction side valve creates a large local pressure drop that consumes NPSHa and causes cavitation.
[Calculation] With the valve half open the zeta rises sharply and the differential head equals zeta*v2/2g=1.0m, so NPSHa falls from 3.2 to 2.2m against NPSHr and cavitation occurs at the throttling point.
[Design Omission] The suction valve was wrongly used to regulate flow, so throttling occurred on the suction side and cavitation followed.

Correct Solution

1) Keep the suction valve fully open and never use it for flow regulation: throttling on the suction side consumes NPSHa, so the inlet pressure stays adequate;
2) Regulate the flow with a discharge valve or variable speed instead: regulating on the discharge side does not consume NPSHa, so the flow is controlled correctly;
3) Select a full-bore low-resistance type for the suction valve: a low zeta gives a small pressure drop;
4) Design the suction valve with a fail-open position: an inadvertent closure causes cavitation, so this prevents it;
5) Check NPSHa with the suction valve fully open: fully open is the normal condition, so the duty is met;
6) Install inlet pressure monitoring to identify throttling: throttling lowers the pressure, so this provides a diagnostic;
7) Commission the pump and measure the inlet pressure with the suction valve fully open: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the prohibition on throttling the suction side in the operating instructions: the original throttling was the root cause, so the procedure must always include it.

Checklist

References

GB/T 13006-2013 Centrifugal Pumps - NPSH

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL