E44-902 · Siphon and Backflow · Siphon Pipe · ★★
Air lock, flow blockage, stoppage
[Mechanism] Air accumulates at the high point of the piping and forms an air lock; because gas is compressible, the liquid column can no longer be transmitted continuously and the flow stops.
[Calculation] An accumulated gas volume V_g=0.5 L at the high point reduces the flow area of that section by 80%, sharply raising the resistance until the flow stops; venting restores it.
[Design Omission] No venting at the highest point, an adverse pipe slope (sag points trapping air), and no slope-direction check.
1) Install an automatic vent valve at the highest point (venting as soon as air accumulates), because gas collects at the highest point and forms a lock and venting restores the flow, thereby eliminating the air-lock stoppage;
2) Verify the pipe slope so it falls along the flow direction (i≥0.003), because a favorable slope lets air drain with the flow while an adverse slope traps air at sag points, thereby correcting the slope to suppress accumulation;
3) Raise the pipe top locally into a hump at the highest point and add a gas collection pocket, because the pocket holds the air without blocking the flow and is drained periodically, thereby keeping the peak from locking;
4) Raise the velocity to 1.2–1.5 m/s (originally 0.8 m/s), because at low velocity gas separates and floats up slowly while higher velocity carries it out, thereby suppressing the air lock;
5) Provide a transparent sight glass plus manual venting at the high point (as backup), because if the automatic valve fails a manual path is needed for double protection, thereby making venting independent of a single point;
6) Run an air-lock test (fill with water and check the high point is fully vented), because the design missed the venting and the test confirms there is no air lock, thereby verifying venting is effective;
7) Monitor the pressure difference during operation (alarm on a sudden Δp rise), because an air lock raises the local resistance first, earlier than the stoppage, thereby monitoring the pressure difference for early warning;
8) Write the slope-direction check and high-point venting into the piping installation checklist, because the root cause of the air lock is an adverse slope with no venting, thereby the installation controls it to prevent locking.
GB/T 20801.3-2020 Design code for industrial metallic piping