E44-901 · Siphon and Backflow · Elevated Tank · ★★
Interruption, material starvation, stoppage
[Mechanism] The level in the elevated tank drops below the siphon outlet, air is drawn in and destroys the vacuum, breaking the liquid column.
[Calculation] When the minimum level H_min=0.2 m is 0.5 m below the outlet, the inlet is exposed and draws in air, breaking the flow; safety requires H_min≥ the outlet +0.3 m=0.8 m.
[Design Omission] No minimum level reserved, no outlet-elevation check, and no low-level alarm.
1) Provide minimum-level protection so that H_min≥ the outlet +0.3 m (the original 0.2 m is insufficient), because the inlet must stay below the level to be submerged and draw liquid and breaks as soon as it is exposed, thereby keeping the submergence depth and maintaining the vacuum;
2) Verify that the outlet elevation is ≥0.3 m below the tank-bottom drain, because the closer the outlet is to the tank bottom the lower the usable level and the less likely it is to be exposed, thereby extending the continuous siphon time;
3) Install a make-up pump below the tank interlocked on level (automatic start at the low limit), because withdrawal outstrips feed and empties the tank while make-up holds the level, thereby preventing an empty-tank stoppage;
4) Add a tank-wall level gauge with low-level alarm (alarm ≤0.8 m), because the level falls gradually before the stoppage, allowing early make-up, thereby monitoring the level and preventing a sudden stoppage;
5) Add a vortex breaker (cross baffle) at the outlet, because low levels readily generate vortices that entrain air while the breaker breaks the vortex and suppresses air entrainment, thereby keeping suction stable even at low level;
6) Run a siphon-stoppage test (draw down to the low limit and check the flow does not break), because the design missed the outlet-elevation check and the measurement confirms the safety margin, thereby verifying the usable level;
7) Limit the discharge-valve flow velocity to ≤ design (the original was too high and drained the tank quickly), because steady discharge slows the level drop and makes exposure less likely, thereby controlling the discharge to steady the suction;
8) Write the minimum level and outlet-elevation check into the elevated-tank operating procedure, because the root cause of the interruption is no reserve level and no outlet check, thereby the procedure controls it to prevent starvation.
GB/T 20801.3-2020 Design code for industrial metallic piping