Pump-Stop Backflow Water Hammer

E44-903 · Siphon and Backflow · Pump Outlet · ★★★

Problem Description

Backflow, water hammer, vibration

Root Cause

[Mechanism] After the pump stops, the outlet check valve fails, and medium from a high level flows back, driving the pump in reverse and inducing water hammer.
[Calculation] A backflow head H=18 m produces a reverse speed n_rev≈1.2n_n; the water-hammer pressure rise is Δp=ρcΔv, and at Δv=2.5 m/s Δp≈2.5 MPa, exceeding the allowable pressure of the pipe.
[Design Omission] The check-valve failure was not detected, no slow closing was provided, and the outlet had no damping.

Corrective Solution

1) Install a slow-closing check valve at the pump outlet (closing time 3–5 s adjustable), because backflow water hammer is caused by an abrupt change in velocity Δv and slow closing reduces Δv from 2.5 to 0.5 m/s and Δp from 2.5 to 0.5 MPa, thereby clipping the peak and protecting the pipe;
2) Overhaul the check valve every quarter to keep it sealed (leakage ≤5 mL/min), because a worn disc leaks and causes backflow while strict inspection keeps it leak-free, thereby cutting off the water source for reverse rotation;
3) Install an air buffer tank at the outlet (volume ≥ pump flow ×5 s), because the tank absorbs and stores energy, damping the water-hammer wave and cutting the Δp peak by 30%, thereby providing buffer protection;
4) Add pump reverse-rotation protection (alarm and trip when speed >10% of rated), because backflow-induced reverse rotation damages the bearings and monitoring trips it, thereby preventing reverse-rotation damage to the machine;
5) Install a water-hammer pressure recorder on the outlet pipe (alarm Δp>1.6 MPa), because water hammer shows first as a pressure spike, earlier than pipe rupture, thereby monitoring the pressure for early warning;
6) Run a pump-stop water-hammer test (measure the Δp peak), because the design missed the slow-closing check and the measurement confirms whether the peak exceeds the allowable, thereby setting the closing time on data;
7) In the pump-stop sequence, close the outlet valve before stopping the pump (sequence interlock), because stopping first allows backflow and a wrong sequence causes hammer, thereby controlling the stop sequence to suppress hammer;
8) Write the slow-closing check valve and water-hammer verification into the pump-station design specification, because the root cause of water hammer is a failed check valve with no slow closing, thereby the specification controls it to prevent hammer.

Checklist

Reference

GB/T 20801.3-2020 Design code for industrial metallic piping