E44-904 · Siphon and Backflow · Siphon Pipe · ★★
Insufficient height, weak suction, stoppage
[Mechanism] The outlet-side elevation is too high, so the vacuum required by the siphon exceeds the limit and the liquid column cannot be held, breaking the flow.
[Calculation] The required vacuum is h_v=H_lift+H_loss; with H_lift=10.5 m and H_loss=0.8 m, h_v=11.3 m >10.3 m limit, so the negative pressure at the top exceeds the limit and the liquid column breaks.
[Design Omission] No lift-height calculation, no h_v≤9.5 m check, and the outlet was not lowered.
1) Lower the outlet-side elevation so that H_lift≤8.7 m (originally 10.5 m, over the limit), because h_v=H_lift+H_loss, each 1 m reduction in H_lift lowers h_v by 1 m, and the top pressure = 10.3−h_v turns from negative to positive, thereby returning the vacuum to the safe range and keeping the liquid column unbroken;
2) Verify h_v≤9.5 m with a 0.8 m margin (originally 11.3 m, over), because the safety limit is the atmospheric water column of 10.3 m and the margin guards against fluctuation-induced stoppage, thereby meeting the design requirement;
3) Enlarge the outlet pipe to reduce resistance (DN150→DN200), because v drops from 2.1 to 1.2 m/s, H_loss from 0.8 to 0.3 m, and h_v by 0.5 m, thereby reducing the vacuum demand;
4) Reduce the elbows from 8 to 3 with R≥5D, because Σξ drops from 4.2 to 1.6 and H_loss falls another 0.3 m, thereby further reducing h_v;
5) Raise the inlet-side level by 0.5 m (originally low), because a higher inlet reduces H_lift and the suction demand, thereby easing the lift burden;
6) Run a siphon-height test (measure the maximum sustainable H_lift), because the design missed the calculation and the measurement confirms the limit, thereby setting the usable height on data;
7) Keep the velocity at 1.2–1.5 m/s to prevent air accumulation (low velocity tends to break), because steady flow maintains the vacuum while varying velocity causes fluctuation and stoppage, thereby controlling the velocity to steady the suction;
8) Write the h_v≤9.5 m check into the siphon design specification, because the root cause of the stoppage is a lift height over the limit, thereby the specification controls it to prevent weak flow and stoppage.
GB/T 20801.3-2020 Design code for industrial metallic piping