E44-600 · Seal Leakage · Ferrule Joint · ★★
Joint leaks, ferrule not bitten into the tube
[Mechanism] The ferrule did not bite into the tube and the joint leaks.
[Calculation] Without the bite there is a gap that leaks.
[Design Omission] The joint was not tightened until the ferrule bit, the ferrule was not selected correctly and nothing was inspected - it stayed loose.
1) Tighten until the ferrule bites into the tube (30N-m, the ferrule edge cutting into the tube wall); without the bite the ferrule-to-tube gap leaked, and the bite stops the leak;
2) Select a matching ferrule (by pipe diameter and material); a mismatch prevents the bite, and a correct fit prevents that;
3) Inspect the bite marks (visual, cut depth uniform); the joint loosens gradually and then leaks, so the marks are inspected;
4) Control the pipe outside diameter (within tolerance, no ovality); an oversize pipe prevents the bite, and controlling the diameter prevents that;
5) Deburr the pipe end (chamfer the end); a burr prevents the bite, and removing it allows the bite;
6) Tighten in one pass only (do not re-tighten, it may crack the tube); repeated tightening cracks the tube, and a single tightening avoids that;
7) Carry out a pressure test (1.5 times the design pressure); without the test the leak went undetected, so the test confirms tightness;
8) Write the bite tightening into the assembly card; the original failure to tighten was the root cause of the looseness, so the assembly card closes the loop.
GB/T 3733-2008 Ferrule Type Pipe Fittings