E44-599 · Seal Leakage · Threaded Connection · ★
Thread seepage, too little tape
[Mechanism] Too little tape leaves the thread gap unfilled and it seeps.
[Calculation] The shortage leaves a gap that seeps.
[Design Omission] The tape was not wrapped sufficiently, not wrapped in the right direction and not inspected - too little was used.
1) Wrap enough PTFE tape (5 turns, wound in the direction of thread tightening); the original shortage left the thread gap unfilled and it seeped, and filling it stops the seepage;
2) Wrap in the same direction as the thread is tightened; the reverse direction unwinds during assembly and the joint seeps, so matching the direction prevents that;
3) Apply pipe thread sealant (anaerobic sealant for reinforcement); too little tape leaves gaps and the sealant fills them;
4) Tighten to the specified torque (torque wrench); a loose joint seeps, and tightening it stops that;
5) Check for seepage (pressure hold leak test); seepage develops gradually into leakage, so it is checked;
6) Select a suitable tape thickness (medium grade); a thin tape seeps, and a thicker one does not;
7) Clean the threads and remove debris (wire brush); debris leaves gaps, and cleaning the threads prevents that;
8) Write the sufficient wrapping and the direction into the assembly card; the original failure to wrap the tape was the root cause of the shortage, so the assembly card closes the loop.
GB/T 7306-2000 Pipe Threads