E44-341 · Excessive Piping Resistance and Pressure Drop · New piping not purged after welding · ★★
Welding slag blocks two spots, cutting the section 40%, gives Δp=0.12MPa, and cuts downstream flow 30%
[Mechanism] Accumulated welding slag cuts the section 40% and v spikes.
[Calculation] Δp=0.12 cuts flow 30%.
[Design Omission] No system purge and no pig run - welding slag clogged the line.
1) After welding, run a whole-line pig plus compressed-air purge, since slag cut the section 40%, gave Δp=0.12 and cut flow 30%, clearing the slag;
2) Run a bore test to confirm full clearance, since hidden blockage is hard to see, verifying passage;
3) Control internal weld slag and back-purge with argon, since slag originates at the weld, controlling welding;
4) Fit temporary strainers to catch slag, since any remaining slag re-clogs, temporary filtration;
5) Monitor downstream flow to catch the drop early, since blockage cuts flow, monitoring flow;
6) Add a strainer at the pump inlet, since slag damages the pump, inlet filtration;
7) Periodically strip and inspect welded sections, since blind runs accumulate debris, inspecting them;
8) Include purging in commissioning, since the missing purge was the root cause, closing the loop at commissioning.
GB/T 20801.3-2020 Design code for industrial metallic piping