Knowledge Base › Fluid Systems Error Case › False Level Reading from a Foam Layer

False Level Reading from a Foam Layer

E44-650 · Level Control Failure · Foam layer · ★★

Problem Description

Foam layer, falsely high reading, false measurement

Root Cause

[Mechanism] The foam layer makes the measurement read high.
[Calculation] The foam causes the error.
[Design Omission] The foam was not avoided, not broken and not compensated for — so it distorted the reading.

Corrective Solution

1) Select guided-wave radar to avoid the foam (the probe passes through the foam layer to the liquid interface): because the original ultrasonic or differential-pressure device was reflected by the surface foam layer (0.3m thick, 90% gas) and read falsely high by 0.3m, the guided-wave radar measures the true interface along its probe, so it avoids the foam and reads the true value;
2) Add antifoam to reduce the layer (spray antifoam, foam height <50mm): because a thick layer increases the error and antifoam lowers it, the error is reduced;
3) Compensate for the foam layer (correct the reading by the foam thickness): because foam reads high and compensation corrects it, the false-high reading is reduced;
4) Raise the probe clear of the foam (distance from the liquid surface ≥0.5m): because proximity touches the foam and distance measures the liquid instead, the error is avoided;
5) Apply temperature compensation to the reading (correct the sound velocity by temperature): because temperature changes offset it and compensation steadies it, the reading is steady;
6) Calibrate the empty-path zero (empty-tank calibration): because foam shifts the zero and calibrating corrects it, the datum is accurate;
7) Inspect the foam periodically (log the foam-height trend): because a thickening layer increases the error and checking gives early warning, the instrument is reselected in time;
8) Write the foam avoidance and compensation into the specification (use guided-wave radar in foaming service): the original failure to avoid the foam was the root cause of the error, so the spec locks it in and specification governs it.

Checklist

Reference

GB/T 25922-2010 Level meters

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL