Siphon Effect on the Level

E44-649 · Level Control Failure · Siphon · ★★

Problem Description

Siphon, offset, liquid drawn off

Root Cause

[Mechanism] The siphon offsets the liquid level.
[Calculation] The siphon causes the offset.
[Design Omission] The siphon was not broken, no valve was fitted and no checks were made — so it persisted.

Corrective Solution

1) Break the siphon to prevent the offset (a DN15 vacuum breaker at the highest point): because the original low-set outlet on the discharge line formed a siphon that kept drawing liquid after the pump stopped and dropped the reading (0.2m down), breaking the vacuum interrupts it so the level returns to the true value;
2) Add a siphon-breaker hole (drill a Φ3 hole at the top of the pipe): because a siphon offsets the reading and the hole interrupts it, siphoning is prevented;
3) Calibrate the level against the actual value (compare with a gauge): because a siphon offsets it and calibration corrects it, it is confirmed;
4) Control the elevation difference on the connection (outlet above the upstream liquid surface): because a difference siphons and no difference stops it, siphoning is prevented;
5) Select a check valve (closing when the pump stops): because backflow siphons and the check valve stops it, reverse draw-off is prevented;
6) Check for siphoning (check the discharge after the pump stops): because gradual siphoning offsets the level and checking gives early warning, it is broken in time;
7) Limit the liquid velocity against siphoning (reduce the velocity): because too fast siphons and limiting the velocity reduces it, siphoning is prevented;
8) Write the siphon breaking and check valve into the process card: the original failure to break the siphon was the root cause, so the card locks it in and the process governs it.

Checklist

Reference

GB/T 50235-2010 Industrial metallic piping construction