Needle Valve Throttling Noise

E44-862 · Throttling Noise and Vibration · Needle valve · ★★

Problem Description

The narrow throttling gap of the needle valve gave an outlet velocity of 70m/s and a squeal of 92dB(A)

Root Cause

[Mechanism] The extremely small flow section of the needle valve makes the velocity rise sharply, forming a high-frequency squealing jet.
[Calculation] Gap width δ<0.3mm, v=Q/A≈70m/s, and the squeal frequency lies in the high audible band.
[Design Omission] No enlarged bore, no silencing, no switch to a large-flow valve.

Corrective Solution

1) Enlarge the bore to cut the speed (enlarge downstream of the needle valve or switch to a large-flow valve, v from 70 down to ≤30m/s), since the original narrow gap at v70m/s squealed, thus enlarging the bore cuts the speed;
2) Verify the outlet velocity (≤30m/s), since exceeding it squeals and verification controls it, thus verifying velocity;
3) Add a silencer (resistive, insertion loss ≥12dB), since the bare valve radiates 92dB(A) and silencing lowers it, thus silencing;
4) Switch to a large-flow valve (a large-bore needle valve or ball valve), since narrow squeals and the replacement flows freely, thus replacing the valve;
5) Monitor the noise (sound-level meter, alarm >85dB(A)), since gradual growth approaches the limit and early detection catches it, thus monitoring noise;
6) Run an acoustic test (measure Lw), since the lack of testing left the squeal undetected and the test reveals the level, thus testing sound;
7) Control the opening to steady it (operate ≥30%), since a small opening narrows the gap and squeals and control steadies it, thus controlling the opening;
8) Write the bore enlargement and silencing into the specification, since the original lack of enlargement is the root cause of noise and locking it in closes the loop, thus controlling it in the spec.

Checklist

Reference

GB/T 17213.1-2015 Industrial-process control valves