Knowledge Base › Fluid Systems Error Case › Gate Valve Half-Open Vibration

Gate Valve Half-Open Vibration

E44-861 · Throttling Noise and Vibration · Gate valve · ★★

Problem Description

A gate valve at 40% half-open produced downstream vortex vibration with a stem amplitude of 0.6mm

Root Cause

[Mechanism] When the gate valve is half-open, large-scale vortex shedding occurs behind the gate, and the vortex frequency approaches the structural natural frequency, inducing vibration.
[Calculation] Vortex frequency f=St·v/d≈6Hz, close to the natural frequency, amplitude 0.6mm; pulsating pressure ±0.1MPa.
[Design Omission] No full-open operation, no working-position verification, no switch to a dedicated control valve.

Corrective Solution

1) Open fully to avoid half-open (use a dedicated valve for throttling, and keep the gate valve fully open or fully closed), since the original 40% half-open put the vortex frequency near the natural one and vibrated, thus full-open steadies the flow;
2) Verify the working position (keep the nominal opening clear of the sensitive region), since being off vibrates and verification keeps it safe, thus verifying the position;
3) Switch to a control valve (use a cage valve or butterfly valve for throttling), since weak vibrates and the replacement is suitable, thus replacing the valve;
4) Add supports (brackets at both ends of the valve body), since sway vibrates and support steadies it, thus supporting;
5) Monitor the vibration (measure the stem amplitude, alarm >0.2mm), since gradual vibration approaches cracking and early detection catches it, thus monitoring vibration;
6) Run a vibration test (measure the frequency response), since the lack of testing left the vibration undetected and the test reveals the level, thus testing vibration;
7) Control the flow to steady the speed (limit v), since changing conditions drift the vortex frequency and steadying moves it away, thus controlling speed;
8) Write the full-open and position verification into the specification, since the original lack of opening is the root cause of vibration and locking it in closes the loop, thus controlling it in the spec.

Checklist

Reference

GB/T 12234-2019 Gate valves for petroleum and natural gas industries