E44-860 · Throttling Noise and Vibration · Nozzle · ★★
The nozzle outlet velocity of 55m/s gave jet noise of 94dB(A)
[Mechanism] The nozzle contraction produces a high-speed jet, and the turbulence and shock waves radiate strong noise.
[Calculation] Outlet v=55m/s, Mach number Ma=0.16, and the noise Lw grows with v⁸.
[Design Omission] No flared opening, no silencing, and the outlet straight pipe is too short.
1) Flare the nozzle to cut the speed (gradually expand the outlet to v≤30m/s), since the original v55m/s jet gave 94dB(A), thus flaring cuts the speed;
2) Verify the outlet velocity (v≤30m/s or Ma≤0.3), since exceeding it makes noise and verification controls it, thus verifying velocity;
3) Add a silencer (resistive, insertion loss ≥15dB), since the bare pipe radiates 94dB(A) and silencing lowers it, thus silencing;
4) Lengthen the straight pipe (outlet ≥10D for gradual expansion), since short impacts the wall and long diffuses, thus lengthening;
5) Monitor the noise (sound-level meter, alarm >85dB(A)), since gradual growth approaches the limit and early detection catches it, thus monitoring noise;
6) Run an acoustic test (measure Lw per GB/T3767), since the lack of testing left the noise undetected and the test reveals the level, thus testing sound;
7) Control the pressure drop to steady it (limit Δp), since changing conditions make noise and steadying controls it, thus controlling the drop;
8) Write the flaring and silencing into the specification, since the original lack of flaring is the root cause of noise and locking it in closes the loop, thus controlling it in the spec.
GB/T 3767-2016 Determination of sound power levels of noise sources using sound pressure