E44-859 · Throttling Noise and Vibration · Multi-hole valve · ★★
Partial blockage of a multi-hole flow-evening valve raised the noise back to 90dB(A)
[Mechanism] A multi-hole valve reduces noise by letting multiple small jets interfere with each other; partial blockage concentrates the jets and defeats the noise reduction.
[Calculation] The number of effective holes drops from 12 to 7, the single-hole velocity rises 70%, and the noise rises back to 90dB(A).
[Design Omission] No anti-clog type selected, no unclogging, no hole monitoring.
1) Select an even-flow multi-hole design (anti-clog self-cleaning hole pattern), since the original blockage raised the single-hole velocity 70% and the noise back up, thus selecting the holes cuts the noise;
2) Verify the sound level (outlet ≤85dB(A)), since exceeding it disturbs and verification meets it, thus verifying sound;
3) Add cleaning and anti-clogging (an upstream filter to keep particles from clogging the holes), since clogging makes noise and cleaning clears it, thus cleaning and preventing;
4) Raise the downstream pressure (steady the pressure after the valve to cut jet strength), since low pressure makes noise and raising eases it, thus raising pressure;
5) Monitor the noise (sound-level meter, alarm >85dB(A)), since gradual growth approaches the limit and early detection catches it, thus monitoring noise;
6) Run an acoustic test (measure Lw), since the lack of testing left the noise undetected and the test reveals the level, thus testing sound;
7) Control the opening to steady it (moderate operation), since changing conditions make noise and control steadies it, thus controlling the opening;
8) Write the hole selection and cleaning into the specification, since the original lack of selection is the root cause of noise and locking it in closes the loop, thus controlling it in the spec.
GB/T 17213.1-2015 Industrial-process control valves