E44-044 · Insufficient Vessel Strength and Wall Thickness · Pressure Vessel Opening · ★★★
A large opening was not reinforced; stress concentration produces a 30 mm long crack at the edge of the opening and leakage
[Stress Concentration] The stress concentration factor at the opening is Kt=2.5, so the local σ exceeds the limit.
[Fatigue] The crack propagates under alternating load.
[Design Omission] No reinforcing pad was provided and the area-replacement method was not used for reinforcement, so the weakened opening caused cracking.
1) Reinforce the opening by the area-replacement method, because the opening has a stress concentration Kt=2.5 and the local σ exceeds the limit, causing a 30 mm long crack, so the area-replacement method restores the strength;
2) Provide a reinforcing pad or a thick-wall nozzle, because the reinforcement shares the stress at the edge of the opening and lowers Kt, thereby reinforcing it;
3) Check the reinforcement extent and thickness, because insufficient extent or thickness means inadequate reinforcement, so it must be checked quantitatively;
4) Use a smooth transition at the edge of the opening to lower Kt, because a smooth transition makes the stress flow smoothly and lowers Kt, thereby reducing the stress;
5) Inspect the welds for cracks, because the crack starts at the weld, so it must be detected;
6) Perform a fatigue assessment for alternating load, because the alternating load makes the crack propagate, so fatigue must be assessed;
7) Perform a pressure test to check for no seepage at the edge of the opening, because seepage means leakage, so it must be verified;
8) Incorporate reinforcement into opening design, because the original lack of reinforcement is the root cause of the cracking, so it must be included in design.
GB/T 150.3-2011 Pressure vessels - Design