E44-043 · Insufficient Vessel Strength and Wall Thickness · Atmospheric Storage Tank · ★★★
A 6 mm design wall thickness was mistakenly replaced with 4 mm; after liquid fill the shell hoop stress σ=pd/2t exceeds σ_s, and the shell bulges and deforms
[Hoop Stress] σ=pd/2t; with t=4, σ=p·D/(2×4) exceeds the allowable value.
[Bulging] Local exceeding of yield produces plastic bulging.
[Design Omission] The strength formula of GB/T 150 was not used for checking and the plate negative tolerance was not controlled, so the thin wall caused bulging.
1) Calculate the required wall thickness with the strength formula of GB/T 150, because the omission allowed t=4 to be mistakenly used and σ=pd/2t to exceed the allowable value, causing bulging, so thickness must be taken per the formula;
2) Include the plate negative tolerance in the thickness selection, because the negative tolerance makes the actual t thinner and σ higher, so an extra margin must be taken;
3) Perform a water-fill leak test before liquid filling, because the test reveals seepage early, so any leak is found and corrected early;
4) Recheck the wall thickness by ultrasonic thickness measurement, because the measurement confirms that the actual t ≥ the design value, so it must be rechecked;
5) Perform 100% weld inspection, because the welds are weak and cracks start at them, so full inspection is required;
6) Verify by an overpressure hydrostatic test, because the hydrostatic test verifies strength, so it must be performed;
7) Provide level and stress monitoring, because overfilling and overpressure raise σ, so monitoring is needed;
8) Incorporate strength checking into vessel design, because the original omission is the root cause of the thin wall, so it must be checked in design.
GB/T 150.3-2011 Pressure vessels - Design