E44-438 · Two-Phase Flow and Gas Binding · Nozzle Gas Blockage · ★★
Bubbles gathering at the nozzle throat shrink the effective orifice area by 50%, atomization worsens, and the product is uneven.
[Mechanism] Bubbles gathering at the throat shrink the flow area by 50%.
[Calculation] Atomization is poor and the product is uneven.
[Design Omission] No upstream venting and no bubble breakup were provided — the cause of the blocked orifice.
1) Fit venting and a static mixer ahead of the nozzle to break bubbles; coalesced bubbles cut the area 50%, ruin atomization and uneven the product, so vent and shear bubbles for a clean spray;
2) Hold the gas fraction ≤2%; more gas blocks the orifice, so limit it;
3) Enlarge the spray orifice to prevent blockage; small orifices block easily, so upsize it;
4) Monitor the atomization droplet size; poor atomization is hard to detect, so watch it;
5) Clean the nozzle periodically; buildup is gradual, so clean it;
6) Filter the chemical to keep particles from gathering; particles worsen blockage, so filter it;
7) Hold a steady supply pressure to prevent pulsation; pulsation promotes blockage, so stabilize it;
8) Write venting into the design; the original bubble coalescence was the root cause of blockage, so gate it at design stage.
GB/T 5657-2013 Technical specifications for centrifugal pumps