E44-791 · Piping Supports and Thermal Expansion · Expansion loop · ★★
Loop height too low, expansion restrained, stress rising
[Mechanism] An insufficient loop arm height leaves the compensation capacity too low.
[Calculation] The short arm makes the compensation < the displacement and the stress rise > the allowable.
[Design Omission] The arm height was neither calculated nor provided — so it must be calculated.
1) Raise the loop (set the arm height from the long-arm formula, ≥ the required compensation): because the original height was insufficient and left the compensation < the thermal displacement with the stress rising > the allowable, raising it absorbs the expansion;
2) Calculate the compensation height (size the compensation with the L-bend / π-bend formulas): because too little restrains the line and calculating reveals it, the height is calculated;
3) Verify the arm length (arm length ≥ 1.2× the calculated value): because a short arm restrains and verifying makes it sufficient, the arm is verified;
4) Allow for the thermal displacement (cold-set the loop with an offset): because without it the displacement is restrained and allowing relieves it, the displacement is allowed;
5) Monitor the expansion (displacement markers, alarm above design): because progressive restraint raises the stress and early awareness helps, the expansion is monitored;
6) Run a hot test (raise the temperature and record the actual displacement): because the original lack of testing left the restraint undiscovered and the test reveals the true displacement, the hot test is run;
7) Control the temperature to prevent a steep ramp (≤50℃/h): because a steep ramp restrains and a slow one keeps it under control, the temperature is controlled;
8) Write the loop raise and the arm calculation into the calculation sheet: the original design omission was the root cause of the inadequate height, so calculation controls the design and the expansion is fully absorbed.
GB/T 20801.3-2020 Design code for industrial metallic piping