E44-975 · Vessel Strength and Wall-Thickness Deficiency · Head · ★★★
Head collapse, buckling, deformation
[Mechanism] The head buckles inward under external pressure/vacuum, because the critical external pressure is below the operating external pressure.
[Calculation] Operating external pressure P_out=0.06MPa, head critical buckling Pcr=0.04MPa (R=900mm, δ=8mm), exceeded by 50%, collapse depth 25mm.
[Design Omission] No head-stability check, no stiffening ring, and no vacuum breaker.
1) Check head external-pressure stability (hold Pcr≥1.5P_out=0.09MPa), since P_out=0.06>Pcr 0.04 caused collapse and the stability check protects it — thus preventing collapse;
2) Add a head stiffening ring (flat bar -60×8, one turn), since a weak head collapses and a ring raises stiffness — thus stabilizing shape;
3) Raise the wall to 12mm (was 8mm), since a thin wall collapses and a thicker one raises stability — thus reinforcing;
4) Fit a vacuum breaker (opens on vacuum), since negative pressure collapses the head and breaking the vacuum balances it — thus preventing vacuum collapse;
5) Run a head external-pressure test (0.09MPa held), since the collapse came from an unvalidated design and measurement confirms stability — thus setting stability by data;
6) Measure collapse depth (every point ≤2mm), since a collapse first shows as a dent and can be replaced early — thus checking collapse;
7) Hold operating vacuum ≤0.03MPa (break if exceeded), since a large vacuum collapses and control stabilizes — thus running to prevent collapse;
8) Write the stability check and ring addition into the calculation book, since the collapse root cause was the missed Pcr check and missing ring — thus locking it in at design.
GB/T 150.1-2011 Pressure vessels