E44-976 · Vessel Strength and Wall-Thickness Deficiency · Flange · ★★★
Flange leak, excessive torque, loosening
[Mechanism] Over-torqued or unevenly loaded flange bolts over-compress and yield the gasket, losing the sealing contact pressure and leaking.
[Calculation] Actual torque M=18kN·m exceeds the gasket sealing need of 12kN·m; gasket stress 320MPa exceeds yield 280MPa, and 60% of the elastic recovery is lost.
[Design Omission] No flange-torque check, no bolt load equalization, and no torquing sequence.
1) Set flange bolt torque to 12kN·m (was 18kN·m), since high M yielded the gasket and leaked, and the correct torque seals — thus sealing;
2) Equalize torque on all 12 bolts (spread ≤10%), since uneven load leaks and equal load levels it — thus equalizing pressure;
3) Upgrade bolt grade (8.8 for 4.8), since a weak bolt loosens and a higher grade holds — thus tightening firmly;
4) Switch to a flexible graphite spiral-wound gasket (recovery ≥30%), since the old stiff gasket leaked and a new one recovers — thus sealing;
5) Run an air-tightness test (1.1× design pressure held), since leaks first show as seepage and can be repaired early — thus finding leaks;
6) Recheck bolt torque (each 12±1kN·m), since an unchecked torque biases load and rechecking equalizes — thus setting tightness by data;
7) Control the tightening sequence (diagonal cross, 3 passes), since random torquing leaks and sequenced torquing is even — thus tightening evenly;
8) Write the torque check and equalization into the assembly card, since the leak root cause was the missed M check and uneven tightening — thus locking it in at assembly.
GB/T 150.1-2011 Pressure vessels