Knowledge Base › Fluid System Error Case › Vessel Overpressure Deformation

Vessel Overpressure Deformation

E44-977 · Vessel Strength and Wall-Thickness Deficiency · Pressure vessel · ★★★

Problem Description

Overpressure, deformation, hazard

Root Cause

[Mechanism] Operating pressure exceeded design pressure with no safety relief; the shell hoop stress went beyond allowable and plastically deformed.
[Calculation] Peak operating pressure 2.4MPa, design pressure 1.6MPa, 50% over, hoop stress 45% over allowable, diameter grew 6mm.
[Design Omission] No safety relief, no design-pressure check, and no overpressure interlock.

Corrective Solution

1) Fit a spring safety valve (set 1.76MPa=1.1×1.6 to lift), since overpressure first shows as a pressure rise and early relief vents it — thus preventing deformation;
2) Set design pressure at peak operating ×1.1 (was missed), since a low design pressure invites overpressure and the correct pressure protects it — thus compliant pressure;
3) Add an overpressure interlock (cut feed at peak pressure), since overpressure is hazardous and an interlock trips it — thus controlling pressure;
4) Recalculate wall thickness for the actual pressure (δ needed 11mm, was 9.8mm), since high pressure raises stress and added thickness lowers it — thus restoring strength;
5) Fit a pressure transmitter plus audio-visual alarm (alert at >1.76MPa), since overpressure first shows as a pressure change, before deformation — thus monitoring and warning early;
6) Run a hydrotest (1.25×1.6=2.0MPa held), since the design pressure was unchecked and measurement confirms no leak — thus setting strength by data;
7) In operation, hold operating pressure ≤1.6MPa (reduce if exceeded), since exceeding design pressure raises stress and pressure control prevents bulging — thus running to prevent deformation;
8) Write the relief and pressure checks into the calculation book, since the overpressure deformation root cause was the missing safety valve and unchecked pressure — thus locking it in at design.

Checklist

Reference

GB/T 150.1-2011 Pressure vessels

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL