Pipe diameter selected too small gives excessive velocity and high friction loss

E44-303 · Excessive Piping Resistance & Pressure Drop · DN80 water transmission pipe, 500m long · ★★

Problem Symptom

The design velocity was 1.5m/s but DN80 was taken, giving v=3.2m/s; the friction loss hf=λL/d·v²/2g=0.42MPa against an allowable 0.15MPa, and there was no water at the end of the line

Root Cause

[High Resistance] The small diameter makes v=Q/A exceed the design velocity and the friction loss hf∝v² rises sharply.
[Out of Tolerance] hf=0.42MPa against 0.15MPa leaves insufficient pressure at the end.
[Design Omission] The pipe was not sized on the design velocity of 1 to 2m/s and the friction loss was not checked, so the diameter was too small.

Correct Solution

1) Enlarge the pipe to DN125 so that v≈1.3m/s, because the original DN80 gave v=3.2 and hf=0.42 against 0.15 with no water at the end, thereby lowering v and reducing hf∝v² with margin to spare;
2) Fix the pipe diameter on the design velocity of 1 to 2m/s, because above it hf rises with the square of the velocity and the energy use is high, thereby making the duty more energy efficient;
3) Check the total friction loss hf=λL/d·v²/2g over the whole line and allow a 20% margin, because the lack of a check caused the exceedance, thereby leaving a margin;
4) Split a long line into sections with relay pumps, because a single section that is too long accumulates hf, thereby distributing the pressure;
5) Select a pipe with a smooth inner wall to reduce λ, because a large λ gives a large hf, thereby selecting a smoother pipe;
6) Pig the line at regular intervals to prevent scale from reducing the diameter, because scale reduces d, raises v and raises hf, thereby preserving the diameter;
7) Raise the pump head to make up the friction loss, because the end of the line needs the pressure, thereby making up the head;
8) Write the pipe diameter and velocity into the hydraulic calculation sheet, because the original omission of the check is the root cause of the excessive resistance, thereby controlling it at the design stage.

Checklist

References

GB/T 20801.3-2020 Design Code for Industrial Metallic Piping