E44-609 · Seal Leakage · Cartridge Mechanical Seal · ★★
Incorrect fitting, leakage, face offset
[Mechanism] Incorrect cartridge dimensions cause the faces to be offset.
[Calculation] The offset separates the faces and they leak.
[Design Omission] The dimensions were never verified, the seal was never aligned and nothing was inspected - it was fitted wrongly.
1) Verify the shaft diameter and reinstall (per the drawing tolerance of +/-0.01); the original incorrect dimensions offset the faces and leaked, so verifying the dimensions stops the offset;
2) Align using the scribed marks (align the scribe lines); a skewed fit offsets the faces, and aligning prevents that;
3) Control the gland parallelism (feeler gauge, even all round); a tilted gland offsets the faces, and controlling the parallelism prevents that;
4) Select a cartridge that matches (by shaft diameter and seal type); a mismatch offsets the faces, and a correct match prevents that;
5) Check the face contact (contact pattern check, continuous colour print); the offset develops gradually and then leaks, so the contact is inspected;
6) Tighten the bolts with equal force (diagonal, torqued); an uneven load offsets the faces, and equal force prevents that;
7) Carry out a static pressure leak test (0.1MPa hold); without the test the wrong fitting went undetected, so the test confirms tightness;
8) Write the dimension check and the alignment into the assembly card; the original failure to verify the dimensions was the root cause of the error, so the assembly card closes the loop.
GB/T 14211-2019 Technical Conditions of Mechanical Seals