E44-013 · Water Hammer and Pressure Surge · Water-Supply Pump Discharge Line · ★★★
A sudden pump trip generated water hammer, raising pressure to 2.4MPa (working pressure 0.6); the pipe burst once a quarter and valves were damaged.
[Direct Hammer] Direct hammer Δp=ρcΔv=1000×1200×1.5=1.8MPa, added to the original pressure reaches 2.4MPa.
[Phase Change] The negative pressure wave vaporizes the line, creating a re-condensation water hammer with a secondary shock.
[Design Omission] No slow-closing check valve or air vessel, and no water-hammer analysis — overpressure burst.
1) Fit a slow-closing check valve at the outlet so closing time >2L/c; direct hammer (closing <Tc) gives Δp=ρcΔv=1.8MPa that added to the original pressure reaches 2.4, over the pipe rating, so slow closing stretches the velocity change and drops Δp sharply;
2) Install a water-hammer relief tank / air vessel to absorb the shock; the compressible gas in the tank absorbs pressure-wave energy, so the peak pressure is cut;
3) Fit a pressure relief valve at the pump outlet to limit pressure; on overpressure it discharges to protect the pipe from bursting, so provide a safety redundancy;
4) Run a water-hammer analysis to compute Δp and wave speed c; experience easily misses the re-condensation secondary shock, so quantify protection;
5) Check piping strength against the water-hammer pressure (2.4MPa); the original was designed for normal 0.6 with insufficient margin, so raise wall thickness or downgrade;
6) Use a soft-stop ramp on pump trip; a sudden stop spikes Δv=1.5 and maximizes Δp, so the ramp reduces Δv;
7) Add wall-thickness margin on critical sections; weak sections break first, so locally strengthen;
8) Bring water-hammer protection into piping design; the missing analysis was the burst root cause, so the design must include it.
GB/T 50265-2010 Pump station design code