High Back Pressure in the Discharge Line Causes High Resistance

E44-1030 · Excessive Piping Resistance & Pressure Drop · Outlet · ★★

Problem Symptom

High back pressure, high resistance, pressure drop

Root Cause

[Mechanism] The discharge pipe is undersized and throttled by a globe valve, so the system resistance far exceeds the pump characteristic, the operating point shifts left and the flow is short.
[Calculation] Design Q=200m3/h, DN150 pipe at v=3.1m/s, friction lambda=0.025 over L=120m gives hf=lambda*L/d*v^2/2g=2.4m; 6 elbows and 1 globe valve give Sum_xi=9.7 and a local hf=1.95m, so total H_sys=4.35m, at which the pump delivers only Q=160m3/h, 20% below design.
[Design Omission] No hydraulic calculation of the line was made, the operating point was never verified, and the diameter was never enlarged.

Correct Solution

1) Enlarge the discharge line to DN200 (v falls to 1.7m/s and hf drops 65%); the high velocity made the friction loss large and enlarging the pipe lowers it, restoring the design flow;
2) Verify the line operating point (recalculate H_sys and take the intersection with the pump Q-H curve, Q>=200m3/h); the original omission skewed the operating point, and checking the point reveals the margin and makes the flow meet the specification;
3) Replace the globe valve with a gate valve (xi 7 to 0.3, local hf from 1.4m down to 0.06m); the globe valve has a high local resistance and changing the valve lowers it, reducing the local losses;
4) Reduce the number of elbows (6 to 3, Sum_xi 9.7 to 5.2); the elbow local resistances accumulate and reducing their number lowers the total resistance;
5) Carry out a hydraulic test of the line (measured DeltaP within 10% of the calculation); the losses were miscounted and measurement confirms the flow, so the data fixes the resistance;
6) Fit a flow meter and an outlet pressure gauge (monitor Q and DeltaP); a change in resistance shows up first as a pressure drop, ahead of the flow shortfall, so the instruments give early warning;
7) Control the outlet valve opening at >=80% in operation (throttling increases the resistance); closing it down raises the resistance and controlling the opening keeps it steady, preventing resistance in operation;
8) Write the hydraulic calculation of the line into the calculation sheet; the root cause of the high back pressure was a missing line resistance verification with no diameter increase, so the calculation sheet closes the loop.

Checklist

References

GB/T 20801.3-2020 Design Code for Industrial Metallic Piping