Filter Pressure Drop Omitted from the System Resistance

E44-1029 · Excessive Piping Resistance & Pressure Drop · Filter · ★★

Problem Symptom

Resistance not counted, pressure drop, sluggish flow

Root Cause

[Mechanism] The filter pressure drop DeltaP_filter was not counted in the system resistance, so the real total resistance exceeded the design and the flow was short.
[Calculation] With filter K=3.0 and v=1.5m/s, DeltaP_filter=K*v^2/2g*rho=3x1.5^2/19.6x1000=344Pa, about 0.35m; the original calculation omitted this 0.35m, the total resistance exceeded design by 12% and the flow was 10% short.
[Design Omission] DeltaP_filter was not counted, the total resistance was never verified, and no differential-pressure gauge was provided.

Correct Solution

1) Include DeltaP_filter=K*v^2/2g*rho in the total resistance (0.35m at K=3.0 and v=1.5m/s); the original calculation omitted this 0.35m so the total resistance exceeded design by 12% and the flow was 10% short, and counting it makes the total match the design;
2) Verify the screen resistance coefficient K at <=2.5 (selecting an open area of >=70%); a large K reduces the flow and the check quantifies it;
3) Change to a high-open-area screen (70% open area replacing 50%); a small open area raises K and changing it lowers K, reducing the resistance;
4) Raise the pump head with a 15% margin (including DeltaP_filter); the filter resistance leaves the terminal under-pressurised and raising the head compensates, securing the flow;
5) Carry out a filter resistance test (measure the DeltaP-Q curve); without the test the real K is unknown, so measurement validates it and the data fixes the resistance;
6) Fit a differential-pressure gauge (report and clean the screen at DeltaP>0.1MPa); blockage raises K and early reporting leads to cleaning, monitoring the resistance;
7) Control the flow at or below design (above that v^2 raises DeltaP_filter); excess raises the filter resistance and controlling it slows the rise, keeping the resistance steady in operation;
8) Write the DeltaP_filter calculation and the K verification into the calculation sheet; the root cause of the omission was a design that never counted the filter resistance, so the calculation sheet closes the loop.

Checklist

References

GB/T 20801.3-2020 Design Code for Industrial Metallic Piping

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »