Excessively Long Piping Run Causes High Resistance

E44-1028 · Excessive Piping Resistance & Pressure Drop · Piping · ★★

Problem Symptom

Long run, high resistance, pressure drop

Root Cause

[Mechanism] An unnecessarily long pipe route makes the developed length L too large, and since hf is proportional to L the losses accumulate beyond the design.
[Calculation] The original routing gave L=350m (the shortest practical route is 220m), v=1.8m/s, DN150; hf=0.025x350/0.15x1.8^2/19.6=1.36m, 0.5m above design, with an 18% shortfall of terminal flow.
[Design Omission] The routing was never optimised, L was never verified, and the run length was never reduced.

Correct Solution

1) Optimise the routing down to L=230m (originally 350m; the detour drove hf 0.5m above design); because hf grows in proportion to L, shortening the run lowers the resistance and the terminal flow returns to the design value;
2) Verify the friction loss hf=lambda*L/d*v^2/2g against the design value (take the shortest path for L); a large L raises the resistance and the check quantifies it;
3) Enlarge the pipe to DN200 (v falls from 1.8 to 1.0m/s); a high velocity raises hf and reducing it slows the rise, reducing the resistance;
4) Provide intermediate boost pumping (sectionalise a long-distance line); a single pump cannot develop enough head and boosting compensates, securing the pressure at the far end;
5) Carry out a resistance test (measure the actual DeltaP against L); without the test the real resistance is unknown, so measurement validates it and the data fixes the resistance;
6) Raise the pump head with a 15% margin; the long run leaves the terminal under-pressurised and raising the head compensates, securing the flow;
7) Control the flow at or below design (above that v^2 raises the resistance); excess raises hf and controlling it slows the rise, keeping the resistance steady in operation;
8) Write the optimised routing and the L verification into the calculation sheet; the root cause of the long run was a routing that was never optimised with no hf check, so the calculation sheet closes the loop.

Checklist

References

GB/T 20801.3-2020 Design Code for Industrial Metallic Piping

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »