E44-321 · Excessive Pipe Resistance and Pressure Drop · A system with 12 reducer points · ★★
12 reducer points accumulate a local loss of 0.1MPa, 25% of the whole-line drop, leaving the end pressure insufficient.
[Accumulated Loss] Multiple reducers stack up in ζ, and ∑hj=0.1 takes 25%.
[Shortfall] The end pressure drops because of the accumulated loss.
[Design Omission] No reduction of reducer points and no bore unification — too many reducers.
1) Unify the bore and cut reducers to ≤4 points, since 12 points gave ∑hj=0.1 (25%) and low end pressure — thus unifying the bore to cut points;
2) Where a reducer is needed, use a gradual taper to cut ζ, since an abrupt step loses heavily — thus tapering;
3) Check ∑ζv²/2g and include it in total resistance, since the accumulated loss was omitted — thus accounting for all loss;
4) Leave a straight run at each reducer, since turbulence loses — thus calming flow;
5) Optimize the pipe-network staging, since multiple stages force reducers — thus staging sensibly;
6) Raise pump head to cover the accumulated loss, since the end needs pressure — thus making up head;
7) Cut unnecessary contractions/expansions, since they lose for nothing — thus cutting reducers;
8) Write the reducer points into the design, since the many original points were the root cause of loss — thus locking it in at design.
GB/T 20801.3-2020 Industrial metallic piping — Design