E44-322 · Excessive Pipe Resistance and Pressure Drop · A pump discharge into a sump at 0.3m submergence (should be ≥1m) · ★★
A 0.3m submergence lets the outlet into the sump draw in a vortex, raising local loss and return resistance and surging the sump level.
[Vortex] Shallow submergence lets the free-surface vortex reach down and draw in air, raising resistance.
[Added Resistance] The vortex makes the return flow turbulent and raises loss.
[Design Omission] No submergence control ≥1m and no flow guidance — shallow submergence.
1) Raise outlet submergence to ≥1m or add a flow hood, since 0.3m let the vortex draw in air, raised return resistance, and surged the level — thus deep submergence to prevent vortex;
2) Point the outlet downward or angled to the sump floor, since an upward outlet vortices easily — thus aiming it down;
3) Fit a vortex breaker to break the surface vortex, since the vortex raises resistance — thus breaking it;
4) Check outlet local loss, since the vortex causes loss — thus accounting for it;
5) Enlarge the sump volume to calm flow, since a small sump vortices easily — thus upsizing;
6) Hold outlet velocity ≤0.5m/s, since high v vortices — thus controlling v;
7) Add level monitoring to hold submergence, since a low level causes vortex — thus monitoring level;
8) Write submergence into the layout, since the insufficient original layout was the vortex root cause — thus locking it in at layout.
GB/T 20801.3-2020 Design code for industrial metallic piping