Siphon Backflow Contamination from an Elevated Tank Discharge Pipe

E44-090 · Siphon and Backflow · Elevated Tank Discharge Pipe · ★★

Problem Description

The low discharge outlet of the discharge pipe forms a siphon that keeps discharging after the pump stops, backflowing and contaminating the downstream vessel

Root Cause

[Siphon] The low outlet of the discharge pipe makes the siphon keep flowing and backflow after the pump stops.
[Calculation] The elevation difference H keeps the siphon flowing until the levels equalize.
[Design Omission] No vacuum break/check valve, so the siphon backflowed.

Corrective Solution

1) Install a vacuum breaker valve at the highest point to break the siphon, because the breaker admits air on pump stop and destroys the vacuum, stopping the siphon, thereby no backflow;
2) Install a check valve on the discharge pipe, because the check valve prevents backflow and closes on pump stop, thereby physically blocking the backflow;
3) Raise the outlet to a siphon-breaking elevation (above the upstream level), because an outlet above the level leaves no siphon head and breaks naturally, thereby preventing it at the source;
4) Interlock pump stop with valve closing, because the interlock closes the valve at the same time as the stop, giving double protection, thereby no backflow at all;
5) Collect any backflow (install a collection trough), because any backflow can be collected without contamination, thereby environmentally friendly;
6) Monitor the level (alarm on the downstream vessel level), because backflow makes the downstream level abnormal and monitoring detects it early, thereby stopping it in time;
7) Commission and verify there is no backflow (check the discharge after pump stop), because backflow is the outcome and measurement is needed, thereby acceptance;
8) Include anti-siphon measures in the piping design, because the original lack of a vacuum break/check valve caused backflow, thereby providing them already at the design stage.

Checklist

Reference

GB/T 20801-2020 Pressure piping code

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »