E44-325 · Excessive Piping Resistance and Pressure Drop · Three Parallel Pumps with Undersized DN150 Header · ★★
Three parallel pumps drove the header velocity to v=4m/s, above the design flow speed; hf=0.3MPa, and the pumps robbed flow unevenly with a 15% spread.
[Undersized] A thin header makes the combined-flow velocity high, hf large, and pumps rob flow from each other.
[Uneven Flow] High resistance spread each pump's flow by 15%.
[Design Omission] The header was not sized for the total flow, and the combined flow was not checked; the header came out undersized.
1) Enlarge the header to DN250 so v≤2m/s; DN150 drove v=4, hf=0.3, and a 15% spread, so upsizing the diameter lowers v;
2) Size the header design velocity for the total flow Q of three pumps; a large total Q needs a larger pipe, so size by Q;
3) Check the combined-flow hf with margin; the combined loss is large, so leave margin;
4) Fit check valves at each pump outlet to prevent reverse flow; flow robbing causes backflow, so prevent it;
5) Arrange the header symmetrically for even flow; asymmetry causes uneven flow, so make it symmetric;
6) Install flow meters to monitor each pump; uneven flow is hard to notice, so monitor it;
7) Use pumps of the same model and characteristic curve; dissimilar units cause spread, so match the model;
8) Record the header hydraulics in the design; the original undersizing was the root cause of resistance, so the design must gate it.
GB/T 20801.3-2020 Design code for industrial metallic piping