Blocked first-stage inlet strainer on a multistage pump causes cavitation

E44-053 · Pump Selection & Cavitation · Multistage Centrifugal Pump · ★★

Problem Symptom

Blockage of the first-stage inlet strainer dropped the inlet pressure, so NPSHa=1.8m against NPSHr=3.0m; the first-stage head fell and the total head dropped from 100m to 88m

Root Cause

[Cavitation Mechanism] The blocked strainer increases the throttling pressure drop at the inlet, so the pressure at the first-stage impeller inlet falls below pv and cavitation occurs.
[Calculation] The blockage increases the differential pressure by 0.8m, dropping NPSHa from 2.6 to 1.8m against 3.0m, and the first-stage cavitation costs about 12% in head.
[Design Omission] No differential pressure alarm was fitted to the strainer and neither the mesh rating nor the flow area was controlled, so the blockage caused first-stage cavitation.

Correct Solution

1) Increase the strainer flow area and control the mesh rating: a small area and a fine mesh clog easily and raise the differential pressure by 0.8m, so enlarging the area and specifying a sensible mesh size is required;
2) Fit a strainer differential pressure alarm and clean the strainer when it trips: the blockage drops NPSHa from 2.6 to 1.8 against 3.0, causing first-stage cavitation and a 12% head loss, so alarm and clean restore the margin;
3) Raise the first-stage inlet pressure so NPSHa is at least 3.5m: the first stage is the most prone to cavitation and therefore needs the largest margin;
4) Select a cavitation-resistant first-stage impeller: a resistant first stage protects the total head;
5) Install pressure monitoring at the inlet: the pressure gauge reveals NPSHa;
6) Clean the strainer at regular intervals: cleaning prevents blockage;
7) Commission the pump and measure the head of every stage against the design values: once the head is recovered there is no cavitation, so this verifies the machine;
8) Include the strainer pressure drop in the inlet design: the original absence of an alarm was the root cause of the blockage and cavitation, so the design must always include it.

Checklist

References

GB/T 5657-2013 Centrifugal Pumps - Technical Conditions