Excessively high installation height on a horizontal centrifugal pump causes cavitation

E44-103 · Pump Selection & Cavitation · Horizontal Centrifugal Pump IS80-50-200 · ★★★

Problem Symptom

The pump was installed at 4.5m against a design limit of 2.5m maximum, the inlet pressure was -0.03MPa, cavitation craters 1.2mm deep formed at the impeller inlet and the flow dropped 15%

Root Cause

[Cavitation] The high installation reduces the inlet static pressure and leaves the available NPSH short.
[Calculation] NPSHa=Pa/rho*g-Hg-hf-Pv/rho*g=2.1m against NPSHr of 3.0m, so bubbles collapse and erode the metal.
[Design Omission] The installation height was never checked against the requirement NPSHa at least NPSHr+0.5, so cavitation occurred.

Correct Solution

1) Lower the installation height to 2.5m maximum: every 1m reduction in Hg raises NPSHa by about 0.01MPa, lifting it from 2.1m to at least 4.0m, so the inlet pressure stays above the vapour pressure and the bubbles do not collapse;
2) Fit an inducer at the inlet to raise NPSHa by about 0.8m: the inducer pre-pressurises the inlet and makes cavitation at the impeller inlet less likely;
3) Enlarge the suction pipe to bring the velocity down to 1.5m/s maximum: as the velocity falls the loss hf falls and NPSHa rises, so the inlet loss is reduced;
4) Fit filtration at the inlet but limit the resistance to 0.3m maximum: strainer resistance adds to the losses and would reduce NPSHa, so the resistance is capped to protect the margin;
5) Install a surge vessel ahead of the pump to stabilise the inlet pressure: it makes up the pressure during fluctuations and prevents transient cavitation;
6) Select a cavitation-resistant impeller material (304 stainless steel): a hard surface resists the cavitation hammering and extends the life;
7) Commission the pump and measure NPSHa at least NPSHr+0.5 with noise no more than 85dB: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the installation height in the cavitation check sheet: it must be traceable, so later installations do not omit it.

Checklist

References

GB/T 13006-2013 Centrifugal, Mixed-Flow and Axial-Flow Pumps - NPSH