E44-104 · Pump Selection & Cavitation · Double-Suction Split-Case Pump 500S-22 · ★★
A cast iron impeller was selected to handle a medium carrying a trace of entrained gas; after 800h the blades had spalled in 3 places and the head dropped 12%
[Material] Cast iron has poor cavitation resistance and erodes and spalls readily.
[Calculation] The cavitation erosion rate is proportional to the differential pressure to the power of 1.5; cast iron at Hv150 is far below stainless steel at Hv of at least 200, so the spalling is fast.
[Design Omission] No cavitation-resistant material was selected, and the spalling followed.
1) Change the impeller to a cavitation-resistant stainless steel such as ZG06Cr13Ni4Mo: a hardness above Hv200 resists the cavitation hammering, so the spalling is slowed;
2) Fit an inducer to raise the inlet pressure: pre-pressurising reduces the cavitation intensity and protects the blades;
3) Control the NPSHa margin to at least 1.0m: a large margin means fewer bubbles and therefore weaker erosion;
4) Install a flow straightener at the inlet to reduce swirl: swirl induces local cavitation, so a uniform flow prevents pitting;
5) Reduce the speed by 10% to raise NPSHa: NPSHr varies as n squared, so the margin increases;
6) Measure the blade thickness at regular intervals and raise an alarm: spalling develops gradually, so early replacement is possible;
7) Commission the pump and verify the head is at or above the design value with no cavitation noise: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the material in the selection for cavitation duty: a medium carrying gas requires a hard surface, so this prevents recurrence.
GB/T 2100-2014 Corrosion Resistant Steel Castings for General Use