Flow beyond the high-efficiency region causes cavitation

E44-236 · Pump Selection & Cavitation · Centrifugal Pump IS200-150-400 · ★★★

Problem Symptom

The pump actually ran at 1.35Q while the high-efficiency region is 0.8 to 1.1Q, so running beyond it raised NPSHr to 4.5m against NPSHa of 3.8m and cavitation occurred

Root Cause

[Cavitation] Flow beyond the right-hand end of the high-efficiency region makes NPSHr rise steeply with Q squared until it exceeds NPSHa and cavitation occurs.
[Calculation] NPSHr varies with Q squared, so raising Q from 1.0 to 1.35 lifts NPSHr by about 1.8 times, from 3.0 to 4.5m against NPSHa of 3.8m.
[Design Omission] The operating flow was not limited and the pump ran beyond the high-efficiency region, so cavitation occurred.

Correct Solution

1) Limit the operating flow to 1.1Q: beyond the region NPSHr rises with Q squared and jumps up, so the cavitation line is not crossed;
2) Fit a restriction orifice or control valve at the discharge to cap the flow: limiting the flow caps Q, so the region is not exceeded;
3) Use variable speed to match the actual demand and avoid large flows: reducing the speed reduces Q, so the duty is optimised;
4) If large flow is needed continuously, reselect a larger pump: the original pump was too small, so the duty is matched;
5) Check NPSHr at the maximum flow: a large Q is the most tightly constrained, so the worst case is covered;
6) Install inlet pressure monitoring as a cavitation warning: large flows cavitate readily, so this protects the machine;
7) Commission the pump at the maximum flow and measure the inlet pressure, confirming no cavitation: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the flow upper limit constraint in the design: the original operation beyond the region was the root cause, so the design must always include it.

Checklist

References

GB/T 13006-2013 Centrifugal Pumps - NPSH

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL