E44-235 · Pump Selection & Cavitation · Custom Centrifugal Pump IS150-125-315 · ★★★
The impeller leading-edge incidence angle was too large, so at off-design conditions the back of the leading edge separated and produced a low-pressure band of local cavitation and banded erosion
[Cavitation] The leading-edge angle did not match the incoming flow and the excessive incidence caused separation on the back face, forming low-pressure cavitation.
[Calculation] With the incidence i equal to the blade angle beta of the blade less the beta of the incoming flow too large, the back-face velocity rises, the local pressure falls below Pv and cavitation occurs in the separated region.
[Design Omission] The impeller leading-edge angle was not optimised for the design duty, so the incidence was unsuitable.
1) Optimise the leading-edge blade angle for the design duty to reduce the incidence: a small incidence gives mild separation, so there is less cavitation;
2) Thicken and smooth the leading edge: the smooth form reduces the local low pressure, so this mitigates the problem;
3) Control the operation to stay close to the design duty: off-design running increases the incidence, so there is less separation;
4) Replace the impeller with one matching the duty if necessary: the original impeller did not match, so the duty is matched;
5) Use a cavitation-resistant material for the leading edge: slight cavitation is hard to avoid, so the edge resists it;
6) Check the inlet flow field with CFD: the separation is visible in the model, so the design is optimised;
7) Commission the pump and verify there is no cavitation noise at the leading edge: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the leading-edge angle optimisation in the design: the original unsuitable angle was the root cause, so the design must always include it.
GB/T 13006-2013 Centrifugal Pumps - NPSH